Sign In | Join Free | My components-electronic.com |
|
Brand Name : SHC
Model Number : SC-TC8
Certification : CNAS、TUV、ITS、CSA、BV、SGS (cost additional)
Place of Origin : China
MOQ : 1 unit
Price : USD 100-500 piece
Payment Terms : T/T, Western Union, MoneyGram, D/A
Supply Ability : 999 units per month
Delivery Time : in 15 work days
Packaging Details : Carton
Standard : IEC62560
Clause : clause 15 figure 8
Test sample : non-dimmable lamp
Material : Plastic
capacitor C2 : 68 nF to 150 nF
resistor R : 3.3 kΩ
potentiometer R1 : 470 kΩ
induction L1 : 3mH
Test Circuit For Testing Non-Dimmable Lamp Or Electronic Switch Fig8
Standards:
The test circuit for testing a non-dimmable lamp or electronic switch is manufactured according to IEC62560 clause 15 figure 8.
Standard description:
15.Abnormal operation
Self-ballasted lamps shall not create hazard under abnormal operating conditions .
Self-ballasted lamps shall be constructed so that as a result of abnormal or careless operation ,the risk of fire and mechanical damage impairing safety of protection against electric shock is obviated .
Appling non-dimmable self-ballasted lamps on a diameter or an electronic switch is to be tested as a possible case of abnormal operation .
Test procedure :
Test non-dimmable lamp in test circuit shown in figure 8.
Determine R1 and S1 setting at which the maximum I r.m.s occurs.
Test at this situation ,and if the lamp passively fails within 60 min ,repeat the test at 10% lower I r.m.s. The lower I r.m.s shall be set in the decreasing potentiometer resistance direction .
Repeat this procedures until stable operation is achieved for minimum 60 min .
Operate the lamp fpr 8H at the above most onerous dimming level (potentiometer adjustment )
Compliance:
Compliance is checked by operating the sample free burning ,vertical cap up position or in the burning position indicated on the packaging at room temperature and at the rated voltage .
In case a voltage range is declared ,the test has to be carried out at the mean voltage of that declared range .
In case of alternative rated voltages ,the test shall be performed separately for each rated voltage .
During this test the lamp shall not catch fire ,or produce flammable gases and live parts shall not become accessible with the standard test finger .
Notice:
1. Please do not damage the appliance shape (such as scratching, bending, etc.).
2. Prevented from dust and moisture environment, in order to avoid the oxidation to affect the dimensional accuracy.
![]() |
IEC62560 Clause 15 Figure 8 Led Bulb Checking Machine Images |